The most important part of milk collecting center is the bulk milk chiller (bmc). When the milk is extracted it is at around 37c. At atmospheric temperature the bacterial growth of milk affect the quality. So to maintain the quality of milk it is necessary to store it at 4c. Milk coolers are design to maintain the temperature of milk at desired point for better handling and storage.
Technical Specification
Description | Dimension (WDH inch) | Volume | Power | Agitator | Shape | Power supply | Pull down time | Refrigerant |
(ltr.) | (kw) | |||||||
RBMC 100 | 26 x 26 x 42 | 130 | 0.8 | 1 | Horizontal-square | 1 ph | 6 hrs. | R22 / R134a |
RBMC 250 | 31 x 37 x 60 | 265 | 1.2 | 1 | Horizontal-square | 1 ph | 6 hrs. | R22 / R134a |
RBMC 500 | 52 x 42 x 60 | 530 | 2.7 | 1 | Horizontal rectangle | 1 ph/3 ph | 6 hrs. | R22 |
RBMC 1000 | 97 x 42 x 60 | 1040 | 4.5 | 1 | Horizontal rectangle | 1 ph/3 ph | 6 hrs. | R22 |
RBMC 1500 | 109 x 58 x 36 | 1500 | 5.9 | 2 | Semi Cylindrical | 1 ph/3 ph | 6 hrs. | R22 |
RBMC 2000 | 109 X 58 X 46 | 2000 | 6 | 1 | Semi Cylindrical | 1 ph/3 ph | 6 hrs. | R22 |
RBMC 3000 | 110 X 63(OD) X 71 | 3000 | 7.8 | 1 | Cylindrical | 3 ph | 6 hrs. | R22 |
RBMC 5000 | 110 X 71(OD) X 79 | 5000 | 11.8 | 2 | Cylindrical | 3 ph | 6 hrs. | R22 |
FEATURES:
Tank- Vertical rectangular tank with opening cover Consisting of:
- Inner Tank, Stainless Steel 304,
- Very efficient full flow argon welded evaporator
- Outer tank, stainless steel 304,
- Insulation with high density non CFC polyurethane foam, 75 mm thickness,
- Cover stainless steel AISI 304, with filling hole and gas spring for easy opening,
- Four adjustable legs (Optional)
- Stainless Steel Butter fly Outlet Milk Filling Valve
Agitation and Homonization
- Low Speed Noiseless Gear Motor (30-35 Rpm)
- Automatic safety stops of agitator at door Opening.
- Automatic programmed Continuous agitation
- Homonization of milk fat in w minutes according to ISO 5708 Standard.
Cooling Equipment
- Separate hermetic type cooling unit with Emerson Copland compressor.
- R 134a/ R407 Green Refrigerant.
Electrical equipments
- Automatic box fastened on the cover opening
- The control interface (Stop, Refrigeration start, continuous agitation start)(Optional)
- The regulation and display of milk temperature,
- The management and control of cooling, agitation and alarms function,
APPLICATION:
- Dairies
- Ice cream manufactures
- Milk outlets
- Provision stores
- Tea depots
Why us?
- Efficient and Power saver Reciprocating Compressor
- Grooved copper tube condenser with aluminum fins
- Corrosion Resistance 304 grade stainless steel body and storage tank
- Copper tube static evaporator for effective and efficient cooling
- Thicker and Dense polyurethane(PUFF) insulation for least heat loss
- Subzero digital thermostat
- Noiseless gear motor agitator
- Dipstick with dipstick chart(optional)